解决方案 <USG5100>sy Enter system view,return user view with Ctrl+Z. [USG5100]diag Warning:Commands in the diagnose view are used for thoubleshooting.Running certain Commands in the diagnose view may cause device anomaly or service interruption.Use such commands under the instructions of HUAWEI technical engineers. [USG5100-diagnose]display reset reason Time Reset Reason 重启原因 15-01-28 10:50:28 Command reboot 使用reboot命令重启 15-01-05 11:33:54 Command reboot 使用reboot命令重启 15-01-05 10:53:37 Command reboot 使用reboot命令重启 14-12-16 19:46:08 Command reboot 使用reboot命令重启 14-11-13 16:15:08 Power off 电源下电重启 14-08-19 17:02:36 Reset key reboot 系统复位重启 14-08-19 16:47:32 Power off 电源下电重启 00-04-03 05:02:15 Power off 电源下电重启 00-04-01 23:55:07 Power off 电源下电重启 <Huawei>system-view [Huawei]diagnose [Huawei-diagnose]display reset-reason [Huawei-diagnose]display inspect black-box record 6 0 0 0 [Huawei-diagnose]display inspect black-box record 8 0 0 0 [Huawei-diagnose]display inspect black-box record 10 0 0 0 [Huawei-diagnose]display inspect black-box record 11 0 0 0 [Huawei-diagnose]display inspect black-box record 12 0 0 0 [Huawei-diagnose]display inspect black-box record 13 0 0 0 [Huawei-diagnose]display inttrace level 1 [Huawei-diagnose]display inttrace level 2 [Huawei-diagnose]display inttrace level 3 [Huawei-diagnose]display lastwords all |